1.1 INTRODUCTION
First of all, thank you for purchasing MyWx,MyGx,MyTx,MyZx,DmyWx,S1M series
redundant power supply.
The MyWx,MyGx,MyTx,MyZx,DmyWx,S1M series is a N+1 hot-swappable /
hot-pluggable redundant power supply. It consists of,
The total output is up to your powers requirements, you can figure out the total
Power’s consumption and check over the specification, the you can find out the
correct configuration.
It delivers full safety redundant (hot-swappable) function and provides the
hot-pluggable feature. In other words, it can offer a more reliable and safer, easy
install / maintain operation in the power energy supply to your system.
Its major function is to deliver the full power and the mean time these power modules
can mutually backup once one of the power modules is defective.
It provides a warning subsystem, include LED display, buzzer alarm, TTL signal etc.,
at the same time, it also indicates the status of the power system.
When all the power modules are at normal condition, it balances the load share and
results the power system increase reliability.
To really discover the power and ease in using the product, we recommend that
you read through this manual carefully.
1.2 PACKING
Your MyWx,MyGx,MyTx,MyZx,DmyWx,S1M package should consist of the followings:
(A) MyWx/MyGx/MyTx/ MyZx/DmyWx or S1M x 1
(B) Accessory pack x 1
(C) Product Manual x 1
Vedere la pagina 0
1 2 3 4 5 6 7 8 9 10

Sommario

Pagina 1

1.1 INTRODUCTION First of all, thank you for purchasing MyWx,MyGx,MyTx,MyZx,DmyWx,S1M series redundant power supply. The MyWx,MyGx,MyTx,MyZx,DmyWx,S

Pagina 2 - 6 7 8 9 10

1.10 TROUBLE SHOOTING If you have followed all directions correctly, these should be no problem. Some common symptoms are: the system doesn’t work

Pagina 3

1.3 MODEL DESINGATION Model number identification X X Y Z X – X XXX X X X 1 2 3 4 5 6 7 8 9 10 1st --- Category X --- blank AC

Pagina 4

8th --- attribute X --- P w/ PFC F w/ EMI filter 9th --- chassis type X --- H horizontal type V vertical type M horizontal + vertical

Pagina 5

1.4 FEATURES MyWx N+1,Hot-swap, Hot-plug, AC input mini redundant power system  Low profile power module for building to the requireme

Pagina 6

MyTx N+1, Hot-swap, Hot-plug, AC input min redundant power system  Low profile power module for building to the requirement  N+1 power

Pagina 7

DMyWx N+1, Hot-swap, Hot-plug, AC input min redundant power system  Low profile power module for building to the requirement  N+1 power

Pagina 8

1.5 DRAWING 1.6 SPECIFICATIONS 1.7 INSTALLATION & TESTING Mount the power system into the system chassis Attach the connectors to main board

Pagina 9

1.8 Hot-swap procedures Please refer to the following when one power module is found defective. (1) Locate the defective power module by examining t

Pagina 10

1.9 PINOUTS AND FUNCTION OF THE CONNECTORS A. Power module defective signal: PIN# VOLTAGE SPECIFICATION 1 GND